Recyclus WCR Knowledge Centre
Guidance for completing Waste Collection Requests, classifying batteries, preparing transport information, and understanding compliance requirements.
Back to WCR FormGetting Started
The Waste Collection Request form is part of the Pre-Acceptance of Waste Process. Customers must complete the form accurately before waste can be accepted to site.
Returning customers should log in before creating a new WCR so their company and contact information can be populated automatically.
How to Complete a WCR
- Confirm your customer and company details.
- Enter collection or delivery information.
- Add one pallet line for each pallet in the shipment.
- Upload clear images for each pallet or container.
- Complete transport, packaging, and declaration details.
- Submit the WCR and wait for confirmation.
Battery Classification Guide
Automotive battery
An automotive battery is a battery of any size or weight used for one or more of the following purposes:
- starter or ignition power in a road vehicle engine
- lighting power in a road vehicle
Industrial battery
An industrial battery or battery pack is of any size or weight, with one or more of the following characteristics:
- designed exclusively for industrial or professional uses
- used as a source of power for propulsion in an electric vehicle
- used as a source of power for electrical propulsion in a hybrid motor vehicle
- unsealed but not an automotive battery
- sealed but not a portable battery
Portable battery
A portable battery or battery pack is a battery which meets all the following criteria:
- sealed
- weighs 4kg or below
- not an automotive or industrial battery
- not designed exclusively for industrial or professional use
Battery pack
A battery pack is a set of batteries connected or encapsulated within an outer casing which is:
- formed and intended for use as a single, complete unit
- not intended to be split up or opened
Sealed battery
The 2008 and 2009 regulations do not define a sealed battery. Defra and the regulators have adopted the International Electrotechnical Commission’s definition of a sealed cell.
A sealed cell may be equipped with a safety device to prevent a dangerously high internal pressure and is designed to operate during its life in its original sealed state.
Defra and the regulators consider a battery which has a valve to allow the release of gas for safety purposes to be sealed. This includes valve regulated lead acid batteries.
VRLA batteries
A VRLA battery is designed to:
- keep the elements of the battery within the case
- re-absorb and recombine gases by chemical reactions
- have a one-way valve to safely release any excess gas that cannot be reabsorbed
- prevent spillage or case rupture by build-up of gas pressure
- not need maintenance such as electrolyte refilling during its lifetime
A VRLA is not a vented battery. Vented batteries are designed to:
- release gases or liquids through vents during normal operation
- allow additional electrolyte to be added during their lifetime
When a battery is not designed exclusively for industrial or professional use
Any battery weighing more than 4kg is classed as industrial or automotive.
Sealed batteries weighing 4kg or below may still be classed as industrial if they are designed exclusively for professional or industrial use.
If a battery producer wants to classify a battery as designed exclusively for professional or industrial use, weighing 4kg or below, they must provide evidence for that classification.
If the battery is available for the general public to buy
If the specific model of battery is widely available for the general public to buy, then it is highly unlikely that it is designed exclusively for industrial or professional use.
If the battery is sold with suggested uses which are not exclusively industrial or professional
It is highly unlikely that the model of battery is designed exclusively for industrial or professional use if:
- it is described as suitable for use within many different items or sectors
- any of these suggested uses are not exclusively industrial or professional
Examples of uses that would not be considered exclusively industrial or professional include:
- an ‘off the shelf’ security or alarm system
- an ‘off the shelf’ fire system
- children’s electronic toys
- solar power storage
- uninterruptable power supply (UPS)
Any models of batteries described as suitable for general or generic use are highly unlikely to have been designed exclusively for industrial or professional use.
Suggested evidence
A battery producer could source a manufacturer data sheet for their specific model of battery as evidence in support of the battery having been designed exclusively for professional or industrial use.
Where the regulator disagrees with the classification of a battery, they will ask the battery producer to provide written confirmation from the battery manufacturer that its specific model number is designed exclusively for industrial or professional use.
ADR Packaging Guide
- Proper Packaging: Lithium batteries must be packed in packaging that meets ADR requirements. This includes packaging designed and tested to prevent damage and leakage during transport.
- Marking and Labeling: Packages containing lithium batteries must be marked and labeled according to ADR requirements.
- Documentation: Proper documentation is essential for the transport of lithium batteries, including a dangerous goods declaration.
- Training Requirements: Personnel involved in packing, handling, and transportation must receive adequate training.
- Segregation Requirements: ADR may specify segregation requirements to separate lithium batteries from other dangerous goods.
UN Number Lookup
Lithium batteries are generally classified under Class 9 as miscellaneous dangerous goods.
- UN 3090 - Lithium Metal Batteries: typically non-rechargeable and contain metallic lithium.
- UN 3480 - Lithium Ion Batteries: rechargeable and contain lithium ions moving between electrodes during charging and discharging.
EWC Code Lookup
EWC code guidance will be added here. For now, customers should contact the Compliance Team if unsure which EWC code to use.
Waste Description and Packaging Examples
Example waste descriptions:
- Mixed lithium batteries
- Portable batteries
- Industrial lithium battery modules
- Lead acid batteries
Example packaging descriptions:
- ADR compliant packaging provided
- Crates secured and terminals taped
- Batteries packed in non-conductive material
- Damaged batteries isolated and packaged separately
Frequently Asked Questions
Can I submit more than one pallet?
Yes. Add one pallet line for each pallet in the shipment.
Can I upload photos?
Yes. Upload clear images showing the contents of each pallet or container.
What happens after submission?
Recyclus Compliance will review the WCR and contact you if further information is required.
Downloads
Downloadable customer guides and PDFs can be added here later.
Contact Compliance Team
Email: compliance@recyclusgroup.com
Telephone: 01902 287561